VERIFIED TIKTOK MEDIA

Normally Open Vs Normally Closed Solenoid Relief Valve

H
Video by @hydraulics.au (hydraulics.au)
Verified Media • Updated August 5, 2026 • Direct Download Ready
Download Video (No Watermark MP4) Download Audio (320kbps MP3)

📊 TikTok Media Details & Stats

Video Title / Caption: Solenoid relief valve selection guide #Hydraulics #Engineering #HeavyMachinery #Lowrider #MiningAustralia
TikTok Creator: @hydraulics.au (hydraulics.au)
Audio Track Name: 🎵 Canyons
Total Play Count: 12,130 views
Total Likes: ❤️ 484 likes
Total Shares: 🔁 32 shares

🎵 Video Info & Details

Here is a look at Normally Open Vs Normally Closed posted by creator @hydraulics.au (hydraulics.au). This video has reached over 12,130 views, 484 likes, and 32 shares on TikTok.

Viewers and creators exploring Normally Open Vs Normally Closed have highlighted several interesting perspectives: Creator @learningautomation: “003 In the previous videos, we explored Normally Open (NO) and Normally Closed (NC) within switches and sensors. This time, we move onto relays. It might seem like another simple lesson, but this is where things start becoming really interesting. Relays were the building blocks of machine control systems long before PLCs existed. They allowed machines to make decisions using physical contacts and logic. Understanding how a relay coil changes contact states is one of the key foundations to understanding PLC programming later on. A simple rule to remember: ⚡ Coil de-energised: • Normally Closed conducts • Normally Open does not conduct ⚡ Coil energised: • Normally Closed does not conduct • Normally Open conducts That same principle follows us into PLC ladder logic too. Although PLC contacts and coils become software instructions rather than physical devices, the thinking stays exactly the same. This is why I’ve deliberately gone through these lessons in stages: Switches → Sensors → Relays → PLCs Build the fundamentals first, and the more advanced topics suddenly become much easier to understand. Many people want to jump straight into PLC programming, but often the basics are what make everything else click.”. Creator @industrial.insigh1: “Testing normally open (NO) and normally closed (NC) contacts. Understanding how these contacts behave is essential when troubleshooting motor control circuits. Follow for more industrial automation troubleshooting tips.”. In another post by @blince.hydraulic: “Normally Open ≠ working open. 🔧 Check the valve's natural state when no control is applied!”.

Expanding on discussion topics around Normally Open Vs Normally Closed offer further context: According to user @bisaioti: “❗ NO vs NC di PLC: Salah Pasang Bisa Fatal Di PLC, NO (Normally Open) dan NC (Normally Closed) kelihatannya sepele, tapi beda fungsi dan dampaknya besar. Kesalahan yang sering terjadi: ❌ emergency stop dipasang NO ❌ limit switch safety pakai NO ❌ tidak paham kondisi normal sistem Akibatnya: ➡️ mesin tetap jalan saat kabel putus ➡️ sistem dianggap aman padahal berbahaya ➡️ risiko ke operator dan mesin Ingat: ✔ NO → tombol start & sensor umum ✔ NC → safety, emergency stop, dan proteksi Kalau kamu sering wiring input PLC, video ini WAJIB kamu save. 👉 Mau belajar wiring & safety PLC yang benar? 🔗 Kunjungi bisaioti.com Belajar PLC, IoT, SCADA, AI, dan Machine Learning.”. In another post by @tesla.harmonics: “🔍✨ Dive into the world of switches with our beginner's guide: "Demystifying Normally Closed and Normally Open Switches!" 🔧🔌 💡 Learn the basics of normally closed and normally open switches as we simplify complex concepts for beginners. 🌐🔍 🛠️ Join us on a journey of discovery as we provide clear explanations and practical examples to empower beginners in understanding switches. 🚀🔗 🔧 Discover how Tesla Harmonics revolutionizes switch understanding, making engineering accessible to all. 🌟🔓 👍 Don't miss out on this enlightening guide! Hit that like button, subscribe for more tech insights, and share the Tesla Harmonics revolution with your friends! 🌟👥”. As noted by @blincehydrualic.j: “Valve logic is defined by the center position. Wrong center, system failure.”.

The video features original audio titled "Canyons". You can stream the audio online or convert it into a 320kbps MP3 file for offline listening.

In this clip, creator @hydraulics.au: "Solenoid relief valve selection guide". This clip is part of trending posts about Normally Open Vs Normally Closed.

Download options are compatible with Android, iPhone, Windows, and Mac devices.

Original TikTok Caption:
Solenoid relief valve selection guide #Hydraulics #Engineering #HeavyMachinery #Lowrider #MiningAustralia

💬 User Ratings & Community Feedback

Alex_TikTokFan 2 hours ago

Downloaded the HD video without watermark! Super fast server speed.

Jessica_R 5 hours ago

The MP3 audio quality for Solenoid relief valve selection guide #Hydraulics #Engineering #HeavyMachinery #Lowrider #MiningAustralia is crystal clear. Works perfectly on my iPhone!

Kevin_VideoEditor 1 day ago

Extracted the background music in high bitrate 320kbps. Thanks for the quick TikTok downloader!

Related TikTok Videos & Recommended Content (20 Selected)

How Many Rakat In Salat Al Fajr 3ds Role Playing Games The Great Condescension Of God I M Not The Only Gluten Free Soy Sauce 𝔏𝔬𝔙 𝔜𝔬𝔲 𝔄𝔏𝔏 ᐢ ᴗ Get Ready To Smile Watch Blueberry Snack Run Blueberries Make How To Change Thermostat Batteries Took Me Way Too Long Beautiful Day Out So I I Was So Scared For Dr Feldman Suggests Immediate Professional Website To Cure Boredom Part Not Funny Didn T Laugh How Many Pounds Of Meat Magic Hot Chocolate Right Here Aquí Les Dejo Algunos Personajes Hobart Champion Elite 225 Nickname For Stuffed Animals